Monday – Friday, 09:00 – 18:00 (UTC+3) WhatsApp 24/7

PPE EN Standards: How to Read the Codes on the Label

EN 397, EN 388, EN ISO 20345, EN 149, EN 14387 and EN 361 — what the codes, levels and filter codes such as A2B2E2K2 on a personal protective equipment label mean for a buyer, and how to write them into a specification in Türkiye.

Short answer

What do the EN codes on a PPE label mean?

An EN code tells you which European standard a piece of personal protective equipment was tested against: EN 397 for safety helmets, EN 166 (replaced by EN ISO 16321-1) for eye protection, EN 388 for gloves against mechanical risks, EN ISO 20345 for safety footwear, EN 149 for filtering face masks, EN 352 for hearing protectors, EN 361 for full body harnesses and EN ISO 20471 for high-visibility clothing. The digits and letters that follow the code give the level of protection — that is where the real information is.

Why a buyer needs to read the standard code

A quote line that says “work gloves — 500 pairs” tells you nothing. Two gloves sold under the same name can be EN 388 cut level 1 and cut level 5; between them there is a large difference in both protection and price.

Reading the standard code gives a buyer three things: quotes that can really be compared, a specification that carries the protection level set by the occupational safety specialist, and a product whose conformity can be shown at an inspection.

Safety helmets — EN 397 and EN 12492

Helmet standards and additional markings
CodeMeaning
EN 397Industrial helmet — basic protection against falling objects
EN 12492Mountaineering / work-at-height helmet — shock absorption from four directions; the chin strap withstands the force specified in the standard without opening, so the helmet stays on the head during a fall
LDLateral deformation — only in EN 397:2012+A1; removed in the 2025 edition
-20°C / -30°CUse at low temperature
+150°CUse at high temperature
440 V ACElectrical insulation — an EN 397:2012+A1 marking; in the 2025 edition this requirement moved to EN 50365:2023 (no insulation claim can be made for ventilated helmets)
Type 1 / Type 2EN 397:2025 only — Type 1: impact on the crown; Type 2: front, side and rear impact as well, with a factory-fitted chin strap that withstands more than the force specified in the standard
MMProtection against molten metal splash

Note: some manufacturers declare additional properties such as flame resistance; because these vary from manufacturer to manufacturer, a specification has to rely on the manufacturer’s own declaration. For work at height an EN 397:2012 helmet is not enough on its own: its chin strap is designed to release at a set force, so the helmet does not stay on the head in a fall. For this work, ask for EN 12492 or EN 397:2025 Type 2.

Work gloves — EN 388, EN 407, EN 511, EN ISO 374

EN 388 gives a glove’s performance against mechanical risks as a four- or six-character code. The order is fixed: abrasion – cut (rotating blade, coup test) – tear – puncture – ISO 13997 cut (A–F) – impact (P). The current edition is EN 388:2016+A1:2018 (adopted in Türkiye as TS EN 388+A1).

EN 388 performance levels
PositionTestScale
1stAbrasion resistance1–4
2ndCut resistance (rotating blade)1–5
3rdTear resistance1–4
4thPuncture resistance1–4
5thISO 13997 cut (2016 revision)A–F
6thImpact protectionP or blank

The higher the digit or letter, the higher the resistance (F is the highest); P shows that the impact test was passed. The A–F cut level introduced with EN 388:2016 is the more reliable one. The threshold behind each level and letter (newtons, cycles, index) is in the standard itself and is not reproduced here; read the value from the product’s EN 388 test report. Where sharp metal is handled, ask for at least C; for sheet-metal edges and glass work, D or above.

Other glove standards
CodeScopeWhen to ask for it
EN 407Thermal risks — 6 positions: burning behaviour, contact heat, convective heat, radiant heat, small splashes of molten metal, large quantities of molten metal (each 1–4; X = not tested)Welding, casting, furnace work. For casting, ask for the 5th and 6th positions separately
EN 511Cold — convective cold (0–4), contact cold (0–4), water permeability (0 or 1 only; 1 = passed the water test)Cold stores, outdoor winter work
EN ISO 374-1Chemicals — Type A/B/C and chemical letter codes (A–T)Chemical handling
EN ISO 374-5Micro-organisms — virus protection is marked separatelyLaboratories, waste, healthcare

The EN ISO 374-1 types describe the breadth and duration of protection: Type A is the widest chemical coverage, Type C the narrowest. The number of chemicals and the breakthrough time each type requires are in the standard itself. Do not write a bare “EN 374” in a specification any more: the EN 374 series moved to the EN ISO 374 series (chemicals: EN ISO 374-1:2016+A1:2018; micro-organisms: EN ISO 374-5:2016); with that change the old “low chemical resistance” beaker pictogram was dropped and the letter requirement became the Type A/B/C scheme. Correct wording: “EN ISO 374-1 Type B, letter codes J, K and L” (read the number of letters each type needs from the standard).

Safety footwear — EN ISO 20345 categories

EN ISO 20345 is the standard for safety footwear with a protective toecap. The category code tells you which additional properties the shoe has beyond the toecap.

EN ISO 20345:2022 categories as given in manufacturer guides (e.g. Sievi)
CategoryAdditional propertiesTypical use
SBBasic requirements — protective toecapGeneral purpose
S1SB + closed seat region + antistatic (A) + energy absorption of the seat region (E)Dry indoor areas, workshops
S1P / S3 / S5The relevant category + metal (steel) insert, penetration test with a nailNot removed in the 2022 edition; write this code if a steel insert is acceptable
S1PL / S1PSS1 + penetration resistance — PL and PS: non-metal insert; the two are tested with different nail diameters (the diameter is in the standard)Indoor areas with nails or swarf
S2S1 + upper resistant to water penetration and absorption (WPA)Wet floors, food, cleaning
S3L / S3SS2 + penetration resistance (L or S) + cleated outsoleConstruction sites, outdoor work
S4Moulded polymer or rubber construction (boot) + antistatic + energy absorptionVery wet environments
S5L / S5SS4 + penetration resistance + cleated outsoleSite boots
S6S2 + water resistance of the whole footwear (WR)Membrane footwear, continuously wet outdoor work
S7L / S7SS3 + water resistance of the whole footwear (WR)Outdoor work that also needs the whole shoe waterproof

Caution: The standard was revised in 2022. Fuel oil resistance (FO) is no longer included in S1–S5 and has to be asked for separately; for slip resistance the SRA/SRB/SRC codes were replaced by a single SR marking (Ø is not a slip rating but the marking for studded or cleated soles exempt from the test). Products certified to the earlier edition may keep carrying SRC until their certificates expire; a new specification should still say SR. Caution: S1P, S3 and S5 were NOT removed. According to manufacturer guides, in the 2022 edition penetration resistance was split into three: P metal (steel) insert, PL and PS non-metal insert (two separate penetration tests). We have not checked these definitions against the standard text; the code on the product’s marking and certificate is what counts. A manufacturer table (Cofra) gives S3 as “S2 + P + outsole with cleats” and S5 as “S4 + P”. A manufacturer example (Sievi): the valid markings are “S3S, S3L, S1P, S1PS, S1PL”. So S3L/S3S is not the “new spelling” of S3 but a different product; writing only S3S in a specification rules out every product with a steel insert. If you want to leave the insert material open, write all three: “S3, S3L or S3S”. For site work with a penetration risk, the S3 family is the one to ask for; for mixed office and warehouse work, if the risk assessment allows, the S1 family may be enough and may be lighter — comfort directly affects whether the shoes are worn.

Respiratory protection — EN 149 (FFP1 / FFP2 / FFP3)

EN 149 filter classes
ClassLevel of protectionTypical useRe-use
FFP1LowestCoarse dust, non-harmful particlesIf marked NR: one shift
FFP2MediumQuartz dust, wood dust, metal fumeNR: one shift
FFP3HighestFine toxic particles, biological agentsNR: one shift

The minimum filtration figure for each class is in EN 149 itself (current edition EN 149:2001+A1:2009); write the class in the specification. NR on the label means the mask is single-use (non-reusable) and designed for one shift; R means limited re-use is possible according to the manufacturer’s instructions. When breathing resistance rises noticeably, the mask is changed before the end of the shift.

Gas filter codes — what does “A2B2E2K2” mean? (EN 14387)

FFP masks (EN 149) only stop particles: dust, mist, fume. They give no protection against gases and vapours such as thinner, ammonia, chlorine or sulphur dioxide. Where there is a gas risk, a gas filter fitted to a half or quarter mask (EN 140) or a full face mask (EN 136) is needed — and one code you may meet in specifications is A2B2E2K2. (Depending on the manufacturer the same filter is also written ABEK2; if all four classes are the same, the two mean the same thing.) The letters show which group of substances the filter is for, the digit shows its capacity.

Caution: This does not mean you should write “FFP is not permitted” in a specification. Disposable valved filtering half masks for gases, or gases and particles, are also a legitimate option (EN 405); these are marked FFA / FFABEK, not FFP — for example, the 3M 4279+ carries FFABEK1P3 R D. Describe the protection you need instead of an absolute ban.

Gas filter types (EN 14387) and colour bands as given in manufacturer guides (e.g. Dräger)
CodeColour bandAgainstWhen buying
ABrownOrganic gases and vapours with a boiling point above 65 °C (thinner, xylene, styrene)For paint, adhesive and solvent work it can be enough on its own if the risk assessment shows no other gas
AXBrownOrganic compounds with a boiling point of 65 °C or below (acetone, butane, methanol)Caution: Single-use and takes no class digit. Not the same job as A; if the two are mixed up, the filter is exhausted before the shift ends
BGreyInorganic gases and vapours (chlorine, hydrogen sulphide)Caution: Does not cover carbon monoxide
EYellowSulphur dioxide and other acid gases declared by the manufacturer (e.g. hydrogen chloride)Caution: Nitrogen oxides are not under this letter — they need a NOP3 filter
KGreenAmmonia and organic ammonia derivativesRefrigeration plants, fertiliser stores, livestock buildings
PWhiteParticles — dust, mist, fume (P1/P2/P3 under EN 143)Supplied together with a gas filter it becomes a combined filter: A2B2E2K2-P3
HgP3Red + whiteMercury vapourCaution: Maximum use time 50 hours — stated by Dräger as an EN 14387 requirement
NOP3Blue + whiteNitrogen oxidesCaution: That it is single-use is printed on the filter

A combined filter carries one band for each type: A2-P3 has two bands, A2B2E2K2-P3 has five. Looking for “two bands” at goods receipt gets the right product rejected. Caution: The table shows the basic types; the standard also defines special types. Carbon monoxide (CO) filters are outside the scope of EN 14387 — the standard’s own scope statement says so; radioactive iodine (Reaktor) filters are also subject to separate rules of use. Both are bought only on the occupational safety specialist’s written selection, with their reference checked separately.

The digit in the code is capacity — not a protection factor. But because capacity is verified at a given concentration, manufacturers also publish the same digit as the maximum concentration at which the filter may be used.

This distinction is an expensive misunderstanding in PPE specifications, and both sides of it matter. In the words of Dräger’s selection guide, filters “are classified according to their capacity (gas filter) or their efficiency (particle filters)”: for a gas filter the class describes capacity, for a particle filter it describes efficiency. So a half mask fitted with A2B2E2K2 does not give a higher protection factor than one fitted with A1B1E1K1 — the filter simply lasts longer. But because manufacturers publish a maximum use concentration per class, a class 1 filter cannot be used above that concentration: there, class 2 is not “better protection” but the only usable option. Read the capacity limit of each class from the filter manufacturer’s user information; this page does not reproduce those values.

The second ceiling, and one that specifications can miss, is this: Dräger’s guide says “Maximum permissible concentration = nominal protection factor × OEL” — the device’s protection factor multiplied by the substance’s occupational exposure limit. The real limit is whichever is lower: the class ceiling or this product. A buyer who writes a class into the specification without looking at the exposure measurement ends up with a device that conforms on paper but falls short on site. That is why the filter class is not a preference but the occupational safety specialist’s written selection, based on measurement; the specification passes that selection on.

Caution: A gas filter has no end-of-service-life indicator — the wearer notices breakthrough by smell. Dräger: “Never use any kind of filtering respiratory protection device… when the contaminant has poor or no warning properties (smell, taste or irritation), such as aniline, benzene, carbon monoxide, and ozone.” For these substances a supplied-air system is needed, not a filtering device. The same applies to oxygen-deficient atmospheres and to unknown concentrations: a filter cleans the air, it does not produce oxygen.

What sets the protection factor is the facepiece — half mask or full face mask — and, on the particle side, the filter’s efficiency class (P1/P2/P3, EN 143). 3M’s European technical bulletin ties the protection factor concept to EN 529; with the same filter, a full face mask gives an equal or higher factor than a half mask (in the bulletin’s own table they are equal for P1 in all three countries and clearly higher for P3). Caution: Numerical protection factors vary from country to country and the bulletin gives no value for Türkiye; instead of writing a factor into the specification, write the facepiece type, the filter code and the face-fit requirement.

Caution: Reference: the current CEN edition of EN 14387 is 2021 (BSI record: “BS EN 14387:2021 supersedes EN 14387:2004+A1:2008”; in Türkiye TSE lists TS EN 14387 as the 2021 edition); on the particle side EN 143:2021 is current. Even so, do not write an edition year on a filter line — and the reason shows up exactly when these two standards are compared. In the EU list of harmonised standards under the PPE Regulation (Commission Implementing Decision (EU) 2026/1279, Annex I) the 2021 edition is listed for EN 143, while EN 14387 is still listed as 2004+A1:2008. So the current CEN edition of a standard and the reference that gives a presumption of conformity for the CE mark do not necessarily move together; for a while, filters on the market will cite the earlier edition in their documents. “Complying with TS EN 14387” covers products made to either document — writing a year narrows the pool of bids for no reason and invites objections. (For the connection standard EN 148-1 things have gone further: the 1999 reference was removed from the list altogether on 4 September 2026 by EU Implementing Decision 2026/1971, and the 2018 edition is not expected to be listed either. The standard stays current at CEN; it is only no longer in the list that gives a presumption of conformity. Use the number without a year to define the connection family.)

Good example

“Combined filter A2B2E2K2-P3 complying with TS EN 14387, for use with a full face mask (TS EN 136); connection EN 148-1 standard thread (Rd40). The filter shall be marked with type, class, colour band, end of shelf life, manufacturer details and the words “EN 14387”, and delivered in unopened packaging. For half/quarter mask (TS EN 140) lines, type and class shall be written according to the exposure measurement (e.g. A2 or A2-P3); where the facepiece and the filter are bought as separate lines, the manufacturer’s written compatibility statement shall be requested.”

Three details make this sentence work. The first is mass: the weight of a filter connected directly to a half mask is limited — manufacturer guides put it as “half masks … for respiratory filters up to 300 g”. Four-gas combined filters with P3, such as A2B2E2K2-P3, can push that limit; for a half mask, read the filter’s weight from the manufacturer’s data sheet and choose a combination that stays within the limit (e.g. A2, A2-P3). Writing a heavy combined filter onto a half mask line buys a product that fits but is not suitable to use.

The second is marking: end of shelf life can also be shown with a pictogram; requiring that “the production date shall be legibly printed” can rule out filters that follow the rules exactly. The third is the connection: the EN 148-1 standard thread (Rd40) is a brand-independent family in which filters from different manufacturers can be used — manufacturers declare this in their own data sheets; some half masks, on the other hand, use a manufacturer-specific bayonet connection, and there the brands are not interchangeable. Write which connection family you want, and if you buy the facepiece and the filter as separate lines, ask for the manufacturer’s written compatibility statement in either case — otherwise the store ends up with two boxes that do not fit each other.

Caution: One last narrowing trap: writing just “ABEK2” rules out legitimate products that carry a different class per gas, such as A2B2E2K1. Write the class per gas; if they should all be the same, say so separately.

High visibility — EN ISO 20471 classes

EN ISO 20471 visibility classes
ClassMinimum area of material (fluorescent background and retroreflective band)Typical use
Class 1SmallestAway from traffic, low-speed areas
Class 2MediumUrban roadworks, warehouses and logistics
Class 3LargestMotorways, night work

The class is set by the area of material alone, which is why the design changes to keep the same class in small sizes. The minimum area values (m²) are in the standard’s table; ask the supplier for the test report that shows the class and the area. When ordering by size, have the supplier confirm that the class is kept in every size.

Work at height — EN 361 and related standards

Fall arrest system standards
CodeComponent
EN 361Full body harness (fall arrest)
EN 358Work positioning and restraint belt
EN 354Lanyard
EN 355Energy absorber — limits the impact force during a fall
EN 360Retractable type fall arrester
EN 362Connector / karabiner

This equipment is Category III: it protects against risks to life. A system that has arrested a fall is taken out of use even if no damage is visible — the energy absorber is single-use.

PPE categories I, II and III and checking the CE mark

In Türkiye, PPE placed on the market falls under the Personal Protective Equipment Regulation (Kişisel Koruyucu Donanım Yönetmeliği, Official Gazette 1 May 2019, No. 30761), prepared in line with Regulation (EU) 2016/425. It sorts PPE into three risk categories (Article 19 and Annex 1), and the conformity assessment route depends on the category (Article 20): Category I — internal production control (Module A); Category II — EU type-examination (Module B) followed by conformity to type based on internal production control (Module C); Category III — Module B followed by either Module C2 (supervised product checks at random intervals) or Module D (quality assurance of the production process). As an exception (Art. 20(2)), Category III PPE made as a single unit to fit a single user follows the Category II route (Module B + C).

On the employer’s side, the regulation on the use of PPE at workplaces (Official Gazette 2 July 2013, No. 28695) requires that PPE used at work is designed and manufactured in accordance with the provisions of the PPE Regulation — the regulation of that name (Article 6(1)(a)).

PPE categories
CategoryRiskExampleCE marking
Category IMinimal risks only (listed in Annex 1)Gardening gloves, sunglassesCE (no notified body number)
Category IIRisks not in Category I or IIISafety helmets, safety spectacles, safety footwearCE (no number)
Category IIIRisks that can cause very serious consequences such as death or irreversible damage to healthFall arrest harnesses, respiratory protection, chemical glovesCE + four-digit notified body number

Practical check: if a Category III product has no four-digit number next to the CE mark, its conformity is doubtful. This is easy to verify at the quoting stage from a photo of the product label. For Category II and III products, the EU type-examination certificate (in the Turkish regulation: AB Tip İnceleme Belgesi) states the type number and the expiry date, and a certificate is valid for no more than five years (Annex 5, points 6.1 and 6.2); there is no type-examination for Category I.

Standards whose number or edition has changed

Standards do not stand still: their number changes, they are split into parts, they are withdrawn. Writing a withdrawn number into a specification leaves newly certified products out of the bidding; locking it to an old edition forces the manufacturer towards a code it cannot meet. The table below shows references on the PPE side that you may meet in an old or incorrect form.

Correct wording today (as of 25 August 2026)
Old / incorrect wordingCurrent referenceWhat happened
EN 374EN ISO 374-1 (chemicals) · EN ISO 374-5 (micro-organisms)The EN 374 series moved to the EN ISO 374 series; the pictogram and the letter scheme changed
EN 166EN ISO 16321-1 (and the relevant part for eye protection)EN 166 was withdrawn in national catalogues and replaced by the EN ISO 16321 series. Products marked EN 166 will still be on the market for a while
EN 397:2012+A1EN 397 — current edition 2025The title changed too: “safety helmets” → “protective helmets”. Writing “current edition” is safer than fixing the year
EN 352 (bare)EN 352-1 (earmuffs) · EN 352-2 (earplugs)Both were renewed in 2020; the A1 amendment to -2 came in 2024
EN 12492:2012EN 12492 — current edition 2025The helmet preferred over EN 397 for work at height and rescue
EN 458:2016EN 458 — current edition 2025The 2016 edition was withdrawn on 31 December 2025. This is not a product standard but a selection guide
EN 14387:2004+A1:2008EN 14387 — current CEN edition 2021Gas and combined filters. BSI record: “BS EN 14387:2021 supersedes EN 14387:2004+A1:2008”. Caution: This row is the best argument for not writing an edition year: the current CEN edition and the reference in the EU harmonised list do not always move together
EN 143:2000EN 143 — current edition 2021Particle filters (P1/P2/P3). Caution: Do not confuse EN 143 with EN 149: EN 149 is the standard for the one-piece FFP mask, EN 143 for the filter fitted to a mask

The full list — references of the 144 standards in our directory, their current editions and which have been withdrawn — is in the standards reference directory (in Turkish). General rule: you do not have to write an edition year in a specification. “Complying with the current edition of TS EN ISO 20345” covers products certified to both the old and the new edition and does not narrow the pool of bids. Fix the edition year only when there is a property that really differs between the two editions.

Turkish adoptions (TS) of the standards on this page — checked on TSE, 23 October 2026
TS reference in forceCorresponds toTSE acceptance dateNote
TS EN 388+A1EN 388:2016+A1:201828.01.2019Replaced TS EN 388:2016
TS EN ISO 374-1EN ISO 374-1:201609.12.2016Amendment /A1:2018
TS EN ISO 20345EN ISO 20345:202228.04.2022Amendment /A1:2024
TS EN 149+A1EN 149:2001+A1:200913.07.2010Replaced TS EN 149:2005
TS EN 14387EN 14387:202112.04.2021—
TS EN 140EN 140:1998+AC:199924.02.2003—
TS EN 136EN 136:1998+AC:199924.02.2003—
TS EN 148-1EN 148-1:201828.01.2019Replaced TS EN 148-1:2003
TS EN 361EN 361:200227.12.2004—
TS EN 355EN 355:200216.04.2004—
TS EN 360EN 360:202304.03.2024—
TS EN 352-1EN 352-1:202015.02.2021—
TS EN 352-2+A1EN 352-2:2020+A1:202408.07.2024Replaced the 2021 TS EN 352-2
TS EN 458EN 458:202521.05.2026Selection guide
TS EN ISO 20471EN ISO 20471:201312.06.2013Amendment /A1:2016

Source: TSE Standard Search, exact-match search by TS number. The TS adoption of the other standards on this page (EN 397, EN 12492, EN ISO 16321-1, EN 407, EN 511, EN ISO 374-5, EN 143, EN 405, EN 354, EN 358, EN 362, EN 166, EN 529, EN 50365) was not checked for this table. In a Turkish specification the same rule applies: write the TS number, and the year only when it matters.

Purchasing checklist

  • Does the specification state the EN standard and the required performance level rather than a brand? (E.g. “EN 388 cut level at least C”)
  • Does the quote give the standard code and level for every line?
  • Is there a CE mark and, on Category III products, a four-digit notified body number?
  • Has the EU declaration of conformity been requested? (In Türkiye the manufacturer supplies it with the PPE or gives its internet address in the instructions — PPE Regulation, Art. 9(8).)
  • Do instructions for use in Turkish come with the product? (The manufacturer prepares them in Turkish and supplies them with the PPE — Art. 9(7).)
  • Has the size breakdown (footwear, clothing, gloves) been settled before ordering?
  • Is the production date recent? (For helmets and harnesses in particular, service life runs from the date of manufacture)

If you send a PPE list for quotation, writing each line this way — standard, level, size breakdown — is what makes the quotes you receive comparable.

Frequently Asked Questions

What do the letters in the EN 388 code mean?

The A–F letter added with the EN 388:2016 revision gives cut resistance under the ISO 13997 straight-blade test. The further along the letter, the higher the cut resistance, and this measurement is considered more reliable than the older rotating-blade test. The newton threshold for each letter is in the standard itself; read the value from the product’s test report.

What is the difference between S1P and S3 safety shoes?

Both have penetration resistance. The difference is how the upper behaves with water: S3 adds resistance of the upper to water penetration (WPA) and a cleated outsole; S1P does not. In dry indoor areas S1P is enough and lighter; on wet outdoor sites S3 is needed. Note: the standard was revised in 2022 and, according to manufacturer guides, penetration resistance is now split into three — P metal (steel) insert, PL and PS non-metal insert (two separate penetration tests). Caution: S1P and S3 were not removed; S1PS/S3S are not their “new spelling” but a different product with a non-metal insert. To leave the insert material open, write all three in the specification: “S3, S3L or S3S”. If full waterproofing is needed, ask for S7, not S3.

What does the 440 V AC marking on a helmet mean?

Under EN 397:2012+A1 it shows that the helmet has electrical insulation; a standard helmet does not have it automatically. In EN 397:2025 this requirement moved to EN 50365:2023 — on helmets certified to the new edition, look for the EN 50365 marking for electrical work; no insulation claim can be made for ventilated helmets.

What should I check on Category III PPE?

There should be a four-digit notified body number next to the CE mark. On Category III products that are re-used, such as fall arresters, the periodic inspection in the manufacturer’s instructions is carried out and recorded; on single-use products (e.g. FFP masks) the expiry date and storage conditions are tracked instead of inspection.

What is the difference between an A2B2E2K2 and an A1B1E1K1 filter?

The letters are the same — both are for organic (A), inorganic (B), acid (E) and ammonia (K) gases. The difference is the digit, and the digit shows capacity: a class 2 filter lasts longer. So on the same mask A2B2E2K2 does not give a higher protection factor than A1B1E1K1. But because capacity is verified at a given concentration, manufacturers publish a maximum use concentration per class; above that value a class 1 filter cannot be used — there, class 2 is not “better protection” but the only usable option. The real limit is always the lower of two ceilings: the class’s maximum concentration, and the device’s protection factor × the substance’s exposure limit. That is why the filter class in a specification is not a preference but the occupational safety specialist’s written selection, based on measurement.

Does an FFP3 mask protect against gases and vapours?

No. FFP masks (EN 149) only stop particles: dust, mist, fume. They give no protection against gases and vapours such as thinner, ammonia or chlorine. Where there is a gas risk, a gas filter (EN 14387) fitted to a half/quarter mask (EN 140) or a full face mask (EN 136) is needed; where there is both gas and dust, a combined filter is used — for example A2B2E2K2-P3. There is also a separate standard for disposable valved filtering half masks for gases and particles (EN 405), which is why a specification describes the protection needed rather than an absolute sentence such as “FFP is not permitted”.

Is it right to write a brand in the specification?

Not unless it is necessary. Writing a brand narrows competition and raises the price. The right way is to write the required standard and performance level; whether equivalents are accepted is stated separately for each line.

Sources

  1. Law No. 6331 on Occupational Health and Safety (Official Gazette 30 June 2012, No. 28339; last amended by Constitutional Court decision of 22/7/2025, E.2024/54, K.2025/163 (Art. 38; in force 9/12/2025)) — in Turkish
  2. Regulation on the Use of Personal Protective Equipment at Workplaces (Kişisel Koruyucu Donanımların İşyerlerinde Kullanılması Hakkında Yönetmelik; Official Gazette 2 July 2013, No. 28695), Art. 6(1)(a) — in Turkish
  3. Personal Protective Equipment Regulation (Kişisel Koruyucu Donanım Yönetmeliği; prepared in line with Regulation (EU) 2016/425; Official Gazette 1 May 2019, No. 30761), Art. 9(7)–(8), 19, 20, Annex 1 and Annex 5 — in Turkish
  4. TSE (Turkish Standards Institution) — Standard Search: current TS references for the standards in the Turkish adoptions table (accessed 23 October 2026)
  5. uvex — protective helmet standards (manufacturer technical information, Turkish site)
  6. uvex — protective glove standards (manufacturer technical information, Turkish site)
  7. 3M Aura 9300+ series technical data sheet — NR (single-use) declaration (PDF)
  8. Dräger — respirator filter types and colour codes; “classified according to their capacity (gas filter) or their efficiency (particle filters)” (manufacturer selection guide, accessed 9 September 2026)
  9. Dräger — Filter Selection Guide: “Maximum permissible concentration = nominal protection factor × OEL”, no filtering devices for substances with poor warning properties, 50 hours for Hg under EN 14387 (PDF, accessed 9 September 2026)
  10. Dräger — filter classes and restrictions of use (manufacturer selection guide, accessed 9 September 2026)
  11. CEN catalogue — EN 148-1:2018 “Threads for facepieces — Part 1: Standard thread connection” (brand-independent Rd40 connection family)
  12. BSI — BS EN 405:2001+A1:2009, valved filtering half masks against gases or gases and particles
  13. Commission Implementing Decision (EU) 2026/1279, Annex I — harmonised standards under the PPE Regulation (EU) 2016/425 (EN 143:2021 · EN 14387:2004+A1:2008 · EN 405:2001+A1:2009 · EN 140:1998 · EN 136:1998)
  14. Commission Implementing Decision (EU) 2026/1971 (Official Journal of the EU, 4 September 2026) — amends 2026/1279; recital (11): the EN 148-1:1999 reference was removed from the list
  15. BartelsRieger — gas filter selection guide: maximum concentration per class and the 300 g filter mass limit on half masks (manufacturer technical information)
  16. 3M 4279+ product page — an example of EN 405 devices being marked “FFABEK1P3 R D”, not FFP
  17. Sievi — penetration resistance markings valid under EN ISO 20345:2022: “S3S, S3L, S1P, S1PS, S1PL” (manufacturer technical information)
  18. Cofra — EN ISO 20345:2022 category table: “S1 P = S1 + P”, “S3 = S2 + P + outsole with cleats”, “S5 = S4 + P”; P = metallic midsole (manufacturer technical information)
  19. BSI — BS EN 14387:2021 record and “supersedes EN 14387:2004+A1:2008”
  20. BSI — BS EN 143:2021 record (particle filters)
  21. 3M EMEA technical bulletin — the protection factor is tied to EN 529 and varies by country (PDF)

How we choose sources, verify figures and date our pages is set out in how we source and verify what we publish. Spotted an error? Write to info@aksco.com.tr — verified errors are corrected.

Send your list — your quote is ready within 1 business day.

A list, a photo or an Excel file — whatever is easiest. On standard items we aim to quote the same business day. Custom production, imports or 50+ line lists can take longer; when they do, we tell you the timeline in writing on the day we receive the request.